Operating Principle
|
|
|
|
|
|
The spaces between the wheels (gear teeth), constitute a fixed volume measurement chamber. Fluid
flow causes the wheels (gears) to rotate, thus separating the fluid into discrete volumes. During one complete
rotation a precise and specific volume of fluid passes through the meter. By counting rotations of the wheels (gears)
the incoming flow is digitized into a series of accurate discrete volumes.
|
| |
|
|
|
|
|
|
|
- Applications:
- Portable Water, Waste Water, Slurry Flows, Chemical Monitoring.
- Fluids: Light to viscous fluids
- Size: 1/4 to 16 inch
- Range: 0.0025 to 5280 GPM
- Accuracy: +/- 0.1% to +/- 2.0% of reading
- Pressure: Max 4560 psi
- Temperature.: -22 to 356 °F
- Viscosity: 1 to 2500 cSt
- Pickup: Hall Effect sensor, magnetic coupling
- Power: 12 or 24 VDC; 24, 110 or 220 VAC
- Outputs: 1 to 2000 Hz, 4-20mA, pulse, alarms
- Materials: Body: aluminum, iron, stainless steel, bronze. Bearings: various. Seals: viton, PTFE, EPDM.
- Connection: Flange, NPT (M/F)
Oval Wheel Brochure
|
|
|
|
|
|
|
|
|
|
- G ¾"
- 232 psig
- For small flow rates 3-30 l/h
- Accuracy ± 0.3-1%
- Operating temperature according to design +14°F to +194°F
- LC-Display with battery supply
- Accessories:
- Electronical Counter, Pick-up, Strainer, Gas Separator, Processing Perifpherals
|
|
|
|
|
- G ¾" - 1½"
- 145 psig
- For small flow rates 1-100 l/h
- Accuracy ± 0.25-1%
- Operating temperature according to design +14°F to +158°F
- Accessories:
- Electronical Counter, Pick-up, Strainer, Gas Separator, Processing Perifpherals
Product Infomation
|
|
|
|
|
|
- G ¼" - 1"
- 362.5-580 psig
- For small flow rates 10-1800 l/h
- Accuracy ± 0.3-2%
- Operating temperature according to design -40°F to +338°F
- For custody transfer admitted
- Accessories:
- Mechanical Counter, Electronical Counter, Pick-up, Strainer, Gas Separator, Processing Perifpherals
Product Infomation
|
|
|
|
|
- G 1" - 4"
- 145-580 psig
- Flow rates 5-1200 l/min
- Accuracy ± 0.1-0.3%
- Operating temperature according to design -40°F to +356°F
- For custody transfer admitted
- Accessories:
- Mechanical Counter, Electronical Counter, Pick-up, Strainer, Gas Separator, Processing Perifpherals
Product Infomation
|
|
|
|
|
|
- G 1" - 16"
- 232-1450 psig
- Flow rates 5-20000 l/min
- Accuracy ± 0.1-0.3%
- Operating temperature according to design -40°F to +554°F
- For custody transfer admitted
- Accessories:
- Mechanical Counter, Electronical Counter, Pick-up, Strainer, Gas Separator, Processing Perifpherals
|
|
|
|
|
- G 1½" - 3¼"
- 232-1450 psig
- Flow rates 5-1200 l/min
- Accuracy ± 0.1-0.3%
- Operating temperature according to design +14°F to +212°F
- For custody transfer admitted
- Accessories:
- Mechanical Counter, Pick-up, Strainer, Gas Separator, Processing Perifpherals
|
|
|
|
|
|
- G 3¼" - 4"
- 87 psig
- Flow rates 2.4-200 m³/h
- Accuracy ± 0.3%
- Operating temperature according to design +14°F to +140°F
- For custody transfer admitted
- Accessories:
- Two-Channel Volume-Proportional Direct Pick-up, Strainer, Gas Separator, Processing Perifpherals
Product Infomation |
Loading Meter Brochure
|
|
|
|
|
- G 1" - 2"
- 87 psig
- Flow rates 50-1200 m³/h
- Accuracy ± 0.3%
- Operating temperature according to design +14°F to +140°F
- For custody transfer admitted
- Accessories:
- Mechanical Counter, Pick-up, Strainer, Gas Separator, Processing Perifpherals
|
|
|
|
|
|
- G 1½" - 3¼"
- 145 psig
- Flow rates 50-1200 m³/h
- Accuracy ± 0.3%
- Operating temperature according to design +14°F to +140°F
- For custody transfer admitted
- Accessories:
- Two-Channel Volume-Proportional Direct Pick-up, Strainer, Gas Separator, Processing Perifpherals
|
|
|
|
Flow
|
|