Operating Principle
|
|
|
|
|
|
Faraday's Law of Electromagnetic Induction -- the magnitude of the voltage induced in a conductive
medium moving through a magnetic field is directly proportional to the fluid velocity.
|
| |
|
|
|
|
|
|
|
- Applications:
- Portable Water, Waste Water, Slurry Flows, Chemical Monitoring.
- Fluids: Any conductive liquid
- Size: 0.08 to 48 inches
- Range: 0.005 to 43,000 GPM
- Accuracy: ± 0.5% of reading
- Pressure: 5500 psig
- Temperature: -4° to 392°F
- Power: 115 or 220 VAC, 12 or 24 VDC
- Outputs: Display: rate and total, 4-20 mA, pulse, hi/lo switch, HART
- Materials: Body: stainless steel; Liner: PVDF, PFA, PP
- Electrodes: Hastelloy C, titanium, platinum, tantalum
- Connection: 150# to 300# ANSI flange or higher
- Approvals: IP65, IP67, IP68, NEMA 4X, explosion proof
Product Information w/ Microprocessor HART Transmitter |
Device Description w/ Analog Transmitter
|
|
|
|
|
- Applications:
- Large Pipes, potable, recirculation, well, waste, salt water, cooling water.
- Fluids: Any conductive liquid
- Size: 1 to 120+ inches
- Range: 1 to 100,000+ GPM
- Accuracy: ±1% to ±2% of reading
- Pressure: 580 psig
- Temperature: -4° to 356°F or higher
- Power: 115 or 220 VAC, 12 or 24 VDC
- Outputs: Display rate and total, 4-20 mA, pulse
- Materials: Body: stainless steel, Hastelloy C, titanium Insulator: PVDF, PFA, etc.
- Electrodes: Hastelloy (std.), titanium, platinum, gold, etc.
- Connection: 150# to 300# ANSI flange
- Approvals: IP65, IP67, IP68, NEMA 4X
Brochure
|
|
|
|
|
|
- Applications:
- Portable Water, Waste Water, Slurry Flows, Chemical Monitoring.
- Fluids: Any conductive liquid
- Size: 1-8 inches
- Range: 0.5 to 500 GPM
- Accuracy: ±2.5% of reading
- Temperature: -4°F to +212°F
- Power: Pulsed DC-field
- Outputs: Display rate and total, 4-20 mA, pulse
- Materials: Body: stainless steel, Hastelloy C, titanium Insulator: PVDF, PFA, etc.
- Electrodes: Hastelloy (std.), titanium, platinum, gold, etc.
- Connection: PN 10 or PN16: 150# flange rating mounting kit provided
- Approvals: IP65, IP67, IP68, explosion proof
- Wear and maintenace-free sensor, due to the absence of any moving parts
- Suitable for flow at high velocities
- Horizontal or vertical installation
- Pulse output adjustable by means of programming switch
Brochure
|
|
|
|
Flow
|
|