Buoyancy Meters


 

Operating Principle

 

 

 

A fixed pivot immersed body in a reservoir changes buoyancy with changes in density. The vertical position of this float is magnetically coupled to a pointer indicating the density on a scale outside the reservoir.

         

DWF

Applications:
Oils, fuel oils, high pressure, low flow, slurries.
  • Fluid: Liquid
  • Size: 1 to 2 inches
  • Flow: Max 44 GPM - slip stream for large lines
  • Span Range: 0.05 to 0.60 Units of Specific Gravity
  • Density Range: 0 to 2.0+ S.G.U.
  • Accuracy: ± 1.0% to ± 2.5% of full scale
  • Pressure: Max 230 psi
  • Temperature: -4 to 300 °F
  • Power: 24 VDC
  • Outputs: Dial indicator, 4-20 mA
  • Materials: 316 SS, optional PTFE liner with Hastelloy
  • Connection: 150# and 300# ANSI flange
 
Flow METRON Technology Technology